DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-238ATM-TRK (Circuit Emulation Service Circuit Pack)
3
If the error occurs 3 times in 10 minutes, the b oard is isolated from the
Packet Bus and the board is al armed. To clear the alarm:
1. Restore this circuit pack to the Pack et Bus with this command
sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS long
d. release board UUCSS
2. If the problem persists and there are no PKT-BUS or port alarms,
replace the circuit pack.
k. Error Type 1538: The ATM-TRK circuit pack is hyperac tive (sending an
abnormal number of co ntrol messages to the processor). Use the
following command se quence for this ATM-TRK circuit pack:
1. busyout board UUCSS
2. reset board UUCSS
3. test board UUCSS long
4. release board UUCSS
5. If this error persists, replace the c ircuit pack.
l. Error Type 1794: LANHO transmit FIFO overflow. The circuit pack’s
transmit buffers have overflowed.
1. Run test board UUCSS r 5.
m. Error Type 2049: ACL Link Failure (link is down). The ATM Control Link
(ACL) has failed, communic ation has been interrupted b etween the SPE
and the ATM-TRK circuit packs on the system, and sig naling-group
parameters are not communica ted across the packet bus.
1. Che ck th e PKT-BU S (Pack et Bus ) and SYS-LINK ( System Link)
maintenance objects, and follow the repair proced ures indicated.
2. Run test board UUCSS against the ATM-TRK circuit pack.
n. Error Type 2306: too many parity errors in data received from the
LAN/packet bus.
If Then
Test #598 fails Replace the circuit pack.
If Then
Test 598 fails. Follow the repair procedures suggested for that
test.