DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-716ISDN-PLK (ISDN-PRI Signaling Link Port)

3
Table 3-301. TEST #643 Signaling Link Board Check
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1700 ABORT Rollabout video abort. The PRI terminal adapter associated with this
D-channel port is detached from the circuit p ack. This is a normal abort
when the rollabout video feature is enabled. To complete test on this port,
either:
1. Re-attach the disconnected PRI terminal adapter and retry test
command, or
2. Disable the rollabout video feature on this circuit pack by entering
change ds1 PCCSS and set the field Alarm when PRI
Endpoint Detached? to y.
8 FAIL The UDS1 circuit pack (TN464C or later) is not in-service.
1. Check the Hardware Error Log for entries logged against UDS1-BD and
consult the UDS1-BD (UDS1 Interface Circuit Pack) Maintenance
documentation for repair procedures.
PASS The UDS1 Interface circuit pack transporting the ISDN-PRI Signaling Link
Port is in-service.
Continued on next page