Maintenance Objects
3-873PE-BCHL (PRI Endpoint Port)
3
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates a disag reement between the switch and the
terminal adapter at the other end of the connection with regard to the
ISDN
call
state of the PRI Endpoint Port. This switch automatically tries to
recover by clearing the call (that is, the call is torn d own). The status
pri-endpoint <extension> command can be u sed to determine the state
of the port.
When running the Short Test Sequence of tests, pay close attention to the
results of the Call State Audit Test (#257).
Table 3-376. PRI Endpoint Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test p ort PCSSp p sh r 1
1 (a) Any None test port PCSSpp sh r 1
15 (b) Any Audit and Update
Test (#36)
18 (c) 0 busyout pri-endpoint
<extension> busyout
port < PCSSpp >
WARNING OFF release p ri-endpoint
<extension> release port
<PCSSpp >
129 (d) None WARNING OFF test port PCSSpp sh r 1
130 (e) None WARNING ON test port PCSSpp sh
257 (f) Any None test port PCSSpp sh r 1
513 (g) Any None WARNING OFF test port PCSSpp sh r 1
76 9 (f) Any None test port PCSSpp sh r 1
1281 (h) Any Conferenc e Circuit
Test (#7) MINOR ON te st por t PCSSpp l r 4
1537 (i) Any NPE Crosstalk Test
(#6) MINOR ON te st por t PCSSpp l r 3
1793 (j) Any None test port PCSSpp sh r 1
3073 (k) Any Service State Audit
(#256) test p ort PCSSp p sh r 2
3585 (l) Any None None
Continued on next page