DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-44ANL-24-L (24-Port Analog Line)

3
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog p ort’s message lamp state (if it has one ) and translations with information in the software.
FAIL The port’s battery feed chip is unable to supply sufficient p ower to the
terminal equipment. This could be a marginal test, and the terminal
equipment may be operating satisfactorily.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, determine whether the customer is
experiencing problems on this line. If so, replace the circuit pac k.
PASS The port’s battery feed chip is able to provid e power to the station
equipment to detect on-/off-hook, but may not be able to supp ly power for
touch-tones. If touch-tones are inoperative on this station, then replace the
circuit pack bec ause this port is inoperative. User-reported troubles on this
port should be investigated by using other port tests, by examining station
wiring, or by examining the station.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
check to ensure that there is a valid board inserted.
Table 3-18. TEST #35 Battery Feed Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page