DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-821MET-LINE (MET Line)

3
MET Electronic Power Feed (#56)

In this test, the software requests that the EPF be turned on for a given p ort. An

attempt is made to turn on the p ower unit to the station. If no current is being

drawn, this probab ly indicates that the station is not c onnected. If an overcurrent

condition is sensed (tha t is, too much current is being drawn), this may indicate a

2000 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this
port. If this error type is present, then release the port via the
release station <extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Battery Feed Test failed. This port is out-of-service.
1. Other ports on this circuit pack are not affected. Place user on a
different port, if available, until a replacement circuit pack can b e
obtained.
2. Replace circ uit pack when availab le.
PASS Battery Feed Test passed. Current flow is properly detected for this
port.
1. If users are reporting problems, examine connections to the port.
0NO
BOARD The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane boar d is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
check to ensure that there is a valid board inserted.
Table 3-355. TEST #35 Port Diagnostic Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page