DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-146ATM-EI (Expansion Interface Circuit Pack)
3
3. Enter add atm pnc
n
(connection number), an d administer the circ uit
pack location and ATM address.
4. Enter change system-parameters duplication and change the Enable
Operation of PNC Duplication field to y.
Removing ATM PNC connections
Standard Reliability
NOTE:
Standard Reliability systems are
not
equipped with PNC duplication.
1. Enter busyout atm-pnc
n
(connection number)
2. Enter remove atm-pnc
n
(connection number)
Critical Reliability
1. Enter status pnc and ensure that the A-PNC is active. If it is not active,
request a PNC interchange using the reset pnc interchange command .
2. Enter busyout pnc-standby.
3. Enter change system-parameters duplication and change the Enable
Operation of PNC Duplication field to n.
4. Enter busyout atm-pnc
n
(port network number).
5. Enter remove atm pnc
n
(port network number) to remove b oth ATM-EI
boards, or enter change atm pnc to remove the B-sid e ATM-EI board.
6. Enter change system-parameters duplication and change the Enable
Operation of PNC Duplication field to y.
Changing circuit pack location or ATM address
Standard Reliability
NOTE:
Standard Reliability systems are
not
equipped with PNC duplication.
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
connections’’ above).
2. Add an ATM PNC connection (see ‘‘Adding ATM PNC connections’’
above).
A-side ATM-EI — Critical Reliability
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
connections’’ above).