DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-448DATA-CHL (Data Channel)
3
FAIL c. If the result of Test #107 i s PASS and the result of Test #108 is PASS,
then the target DATA-CHL is defective.
1. Issue the remove data-module command.
Replace the Processor circuit pack at your earliest convenience.
After the Processor circuit pack has been replaced, its
Time-of-Day clock must be set using the set time command.
2. Restore any busied out function (PRI-CDR/SEC-CDR,
SYS-PRNT, PMS-PRN T/JNL-PRNT, PMS-LI NK) to servic e
before moving on to another activity.
PASS The target DATA-CHL is functioning. Connections can be established over
the target DATA-CHL.
Table 3-189. TEST #111 Data Channel Local Loop Back Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page