DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-61ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
3
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog p ort’s message lamp state (if it has one ) and
translations (such as station type, d ial type, network connec tion) with information
kept in the software. The software is updated with the switchhook state reported
by the port proce ssor. When the ringer is in the off state, this test also turns off the
station’s ringer to prevent con stant ringing caused by defective ha rdware.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-25. TEST #35 Battery Feed Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page