DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-65ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)

3
Figure 3-1. Analog Loop Around and Conference Test
Table 3-27. TEST #47 Loop Around and Conference Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7 ABORT The port was seized by a user for a valid call.
1. Enter display port PCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If
the port is in use, it will be unavailable for certain tests. Wait until the
port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
Continued on next page
TONE
LEVEL
MEASUREMENT
TONE
SOURCE
TDM BUS
BFC*
CODEC
NPE*
ETC.
PORT
* BFC - BATTERY FEED AND HYBRID CHIP
NPE - NETWORK PROCESSING ELEMENT
TN742,
TN769,