DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1162TTR-LEV (TTR Level)
3
!WARNING:
The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12 (France).
Notes:
a. Error code 1 does not indic ate a current error condition. It indicates that
the number of DTMR ports in service was b elow the administered
threshold, but is now equal to or g reater than the threshold. These errors
are typically generated during boot time or ot her transitional states when
the ports are being brought into service.
b. The total number of DTMR ports currently in servic e is below the
administered threshold. To clear the alarm, refer to the repair procedure
described above.
c. Error code 3 does not ind icate a current error cond ition. It indicates that
the number of GPTD ports in service was b elow the administered
threshold, but is now equal to or g reater than the threshold. These errors
are typically generated during boot time or ot her transitional states when
the ports are being brought into service.
d. The total number of GPTD ports currently in servic e is below the
administered threshold. To clear the alarm, refer to the repair procedure
describe abov e.
e. Error code 5 does not indic ate a current error condition. It indicates that
the number of Call Classifier ports (CLSFY-PT) in service was below the
administered threshold, b ut is now equal to or greater than the threshold .
These errors are typically generated during boot time or other tr ansitional
states when the ports are being brought into service.
f. The total number of Call Classifier ports c urrently in service is below the
administered threshold. To clear the alarm, refer to the repair procedure
described above.
g. There are currently no DTMR ports in service. To clear the alarm, refer to
the repair procedure described above.
h. There are currently no GPTD ports in service. To clear the alarm, refer to
the repair procedure described above.
i. There are currently no Call Classifier ports in service . To clear the alarm,
refer to the repair procedu re described ab ove.