DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-966PRI-CDR/SEC-CDR (PRI-CDR Link)
3
Link Retry Test (#215)
This test sends a message to the CDR software process to make a d ata call to
the extension where the CDR output device co nnects to or opens the EIA port to
the CDR output device. If the CDR link is already up , this test is passed without
making any data call or opening the EIA port.
Table 3-421. TEST #213 Link Tear Down Test
Error
Code
Test
Result Description/ Recommendation
40 ABORT Internal system error
50 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1010 ABORT The CDR link has been busied out to out-of-service.
1. Enter the release cdr-link primary|secondary command to release the
CDR link from busyout state.
2. Retry the test cdr-link primary|secondary long command to execute the
test.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The CDR link is torn down.
Continued on next page