DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-353test led
2
technician needs to b e able to disable the attemp ted re-setup of a link. Use of
the busyout command c auses the link to be torn down. If the link is alread y down,
the busyout command will s top periodic re-setup trys on the link.
Output
The following example shows the output for the test journal-printer pms-log
command. The responses d isplay on a test-by-test b asis with one line of data for
each test result.
Field descriptions
test led
This command performs a test on all the LEDs in a specified cab inet. Once the
cabinet is validated and the range of circ uit packs determined , the test led
command turns on all LEDs on the c ircuit packs conta ined in each carrier until a ll
affected carriers are lit. Onc e all the LEDs are on, there is a 2-second p ause, and
then all the LEDs are turned off in the same order. Once all of the repeat cycles
are completed, all affec ted LEDs are restored to the current status.
Port Not applicable (always blank)
Maintenance
Name The name of maintenance object b eing tested:
PMS-PRINT for testing the pms-log printer link
JNL-PRNT for testing the wakeup-log printer lin k
Alt. Name Not applicable (always blank)
Test No The test being executed
Result Test result: Pass, Abort, Fail, Disabled
Error Code Numeric code exp laining why the release failed or ab orted. Refer
to the detailed list of the co des by test number for eac h MO.
test journal-printer pms-log short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
JRNL-LINK 215 PASS
Command Successfully Completed