DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1245UDS1-BD (UDS1 Interface Circuit Pack)
3
PASS The Far CSU Loopback test has successfully began executing. The test will
continue to run until the system technician enters the
test ds1-loop UUCSS
end-loopback/span-test
command or the
release board UUCSS
command.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 3-532. TEST #1213 Far CSU Loopback Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page