DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1093TIE-DS1 (DS1 Tie Trunk)
3
‘‘on-hook’’ that it has been waiting for from the far-end switch. The trunk is
restored to in-service/idle and can be used for calls. Aux Data 57393
indicates delayed external release on PBX disconnect. This error can b e
ignored.
h. Error Type 1793—The DS1 Interface circuit pack is out-of-servic e. See the
appropriate DS1-BD/UDS1-BD (DS1/UDS1 Interface Circuit Pack)
Maintenance documentatio n for details.
i. Error Type 2305Reorder message. The trunk could not be seized. This
error will cause the Trunk Seizure Test (#136) to run and is only considered
a problem if the Seizure Test fails (in which case Error Type 1025 will also
show up). In this case, the trunk may b e put in ‘‘Ready-for-Service’’ state
(shown as ‘‘disconnected ’’ by the status command), whi ch allows only
incoming calls. Run the Trunk Seizure Test (#136) and follow its outlined
procedures.
j. Error Type 2562—Retry Failure error. This error is logged only. It is not a
hardware failure and hence d oes not start any testing or generate any
alarms. This error comes from call proc essing and is generated when a
second attempt (retry) to seiz e an outgoing trunk fails.
k. Error Type 2817Glare error. This error is logged only. It is not a hardware
failure and hence does not star t any testing or generate any alarms . This
error is the result of a simultaneous seizure of a two-way trunk from both
the near-end and the far-end . Attempt to place the c all again. If the error
persists, execute the DS1 Tie Trunk Seizure Test (#136) and follow its
outlined proced ures.
l. Error Type 3840Port Audit and Update Test (#36) failed due to an
internal system error. Enter status trunk command and verify the status of
the trunk. If the trunk is out-of-service, then enter release trunk c ommand
to put it back to in-servic e. Retry the test command.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in Table 3-485 when inspecting
errors in the system. By clearing error c odes associated with the
NPE Crosstalk
Tes t
, for example, you may also clear errors g enerated from other tests in the
testing sequence.