DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-888PKT-BUS (Packet Bus)
3
Error Log Entries and Test to Clear Values
NOTE:
For PKT-BUS, an ON-BOARD alarm indicates a problem with the Packet
Bus itself.
Notes:
a. Within the last minute, packet circ uit packs have reported errors that
indicate a possib le Packet Bus failure. The Aux Data value is 1 or 2,
indicating that only one or more than one Packet circuit pac k
(respectively) have reported a possible Packet Bus failu re.
b. The Maintenance/Test Packet Bus port has determined that there are
Packet Bus shorted-lead or stuc k-lead faults. The Aux Data value
indicates the number of f aulty leads.
c. Packet circuit p acks have detected possible Packet Bus failures via in-l ine
error or background test failure. Examine the Error and Alarm logs for
more s pec ific PKT-BUS e rrors .
Table 3-384. PKT-BUS Error Log Entries
Error
Type Aux Data Associated Test
Alarm
Level
On/Off
Board
Test to Cl ea r
Valu e
01
1. Run the Long Test Sequence. Refer to the appropriate test description and follow the
recommended procedures.
0 Any Any Any test pkt l
1 (a) 1-2 Pac ket Circ uit Pack
Audit Test (#570) MAJOR ON test pkt p l r 2
513 (b) 1-24 Maintenanc e/Test
Circuit Pack Query Test
(#572)
MAJOR ON test pkt p l r 2
1793 (c) Any none
2305 (d) 1-24 Maintenance/Test
Circuit Pack Query Test
(#572)
test pkt p l
3329 (e) 1-7 none WARNING ON test pkt p l
3585 (f) Any none MINOR ON test pkt p l