DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1147TRANS-ID (Translation-ID)
3
TRANS-ID (Translation-ID)
Both the system processor and th e PCMCIA translation card have matching ID
numbers. When the system detects a mismatc h between the two numbers, the
system:
raises a MAJOR off-board alarm (TRANS-ID) against ports 01A or 01B.
displays the warning: TRANS-ID INTERVAL EXPIRATION: x days;
call Lucent distributor immediately. x days is the grace
period during which only Lucent Services logins can save translations.
disables the add , change, remove, and d uplicate co mmands if the
translation ID is not reset prior to the expiration o f the grace period (reset
translation-id -- Lucent Services login req uired)
For information about changing the grace per iod, see ‘‘Changing the g race
period interval’’.

Clearing the alarm

Use the reset system 3 command with the translati on card that matches
the processor(s) in plac e to resolve the condition.
Otherwise, contact authorized Lucent Services personnel or d istributor
immediately. They can reset the translation ID (reset translation-id).
NOTE:
Duplicated systems r aise separate MAJOR, off-board TRANS-ID alarms
agai nst SPE A ( 01A) or SPE B (0 1B).
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
TRANS-ID MAJOR N/A Translation-ID
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board Test to Clear Value
Any None N/A MAJOR OFF Reset the system (reset system 3)
with matching translation and
processor(s). Contact authorized
Lucent personnel to execute the reset
translation-id command (requires
Lucent Services login).