DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-926PMS-PRNT/JNL-PRNT (PMS Printer Link)

3
Link Retry Test (#215)
This test sends a message to the journal p rinter management software process to make a data call to the extension where the p rinter device connec ts to. If the journal printer link is already up , this test passes without making any data call.
Table 3-397. TEST #213 Link Tear Down Test
Error
Code
Test
Result Description/ Recommendation
40 ABORT Internal system error
50 ABORT Internal system error
1. Retry the command at 1minute intervals a maximum of 5 times.
1010 ABORT The link has been busied out to out-of-service.
1. Enter release journal wakeup-log|pms-log command to release the
link from busyout state.
2. Retry test journal wakeup-log|pms-log l command to execute the
test.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The link is to rn dow n.
Continued on next page