DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-18busyout trunk
2
alarms (error type 18) are generated on eac h tone clock circu it pack busied out,
so that INADS can determine the state of the ob jects. The command, release
tone-clock, reactivates the specified tone/clock.
Output
The following example is a display of the busyout tone-clock command.
Field descriptions
busyout trunk
The busyout trunk command places the spec ified installed or uninstalled trunk
group or trunk group me mber in a maintenance busy state. No p eriodic or
scheduled tests are p erformed on the busied out trunk groups or trunk group
members until they are released. When the objec t is maintenance busy it is
deactivated (no c all processing activi ty may include the busied ob ject). A single
group member c an be busied out by sp ecifying the group and member number.
All members in a trunk group c an be busied out b y specifying the trunk g roup
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
tone-clock
location
Physical location (PCC)
Examples:
busyout tone-clock 01c
busyout tone-clock 03d
init
inads
craft
1 (one) none
Port Tone/clock board ad dress (cabinet-ca rrier)
Maintenance Name Circuit pack name: TONE-PT, TDM-CLK, TONE-BD
Alt. name Not applicab le
Result Test result: Pass, Abort, Fail
Error Code Numeric code exp laining why the release failed or ab orted. Refer to
the detailed list of the cod es by test number for each MO .
busyout tone-clock 1a SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01A TONE-PT PASS
01A TDM-CLK PASS
01A TONE-BD PASS
Command successfully completed