DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-806MEDPROPT (TN802 MED PRO DSP PORT)
3
MEDPROPT (TN802 MED PRO DSP
PORT)
The MEDPROPT maintenance object monitors the health of the MEDPRO digital
signal processors (DSPs).
The TN802B MAPD (Multi-Application Platform for DEFINITY) Media Processor
circuit pack p rovides the audio be arer channels for H.323 voice over IP calls.
One TN802B circuit pack has one MEDPROPT media processing resource.
Based on system administration of aud io codecs, a M EDPROPT can handle
either 31 or 22 simultaneous channels of H.323 aud io processing. If the
ip-parameters form specifies only G.7 11 Mulaw or G.711 Alaw as the audio
codecs, the MEDPROPT can service 31 channels. If any other c odec type
(G.723-5.3K, G.723-6.3K, or G.729) is administered , the MEDPROPT can only
service 22 channels.
The MEDPROPT is physically made up o f 11 individual DSPs, but is treated
logically as one por t. If individual DSPs on the TN802B MAPD fail, the
MEDPROPT remains in-service at lower capac ity.
The MEDPROPT is a shared service circuit. It is shared between H.323 trunk
channels and H.323 stations. An id le channel is allocated to an H.323
trunk/station on a call-by-c all basis.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run Full Name of MO
MEDPROPT MINOR/WARNING test port UUCSS or
PCSS [sho rt/lo ng]
[repeat#] | [clear]
TN802 MED PRO DSP PT
Table 3-349. MEDPROPT Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
010 Any Any Any test board UUCCSS
1(a) DSP Capac ity Test
(#1382) ON test board UUCCSS l r5
258(b) DSP C apaci ty Te st
(#1382) WARNING ON test board UUCCSS l r5
Continued on next page