DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-804MEDPRO (Media Processor MAPD Circuit Pack)

3
NT Reset Test (#1381)
This test is destructive.
This test resets the circuit pack. The test is hig hly destructive and c an only be
initiated by a system tec hnician-demanded reset boar d UUCSS command.
Table 3-347. TEST #1381 NT Reset Test
Error
Code
Test
Result Description/ Recommendation
None ABORT System resources required for this test are not available.
1. Retry the reset board UUCSS command at 1-minute intervals a
maximum of 5 times.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the reset board UUCSS command again.
2100 ABORT System resources required for this test are not available.
1. Retry the reset board UUCSS command at 1-minute intervals a
maximum of 5 times.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute the reset board UUCSS command again.
2. If the problem persists, replace the circuit pac k.
PASS The circ uit pack initializes correctly.
1. Run the Short Test Sequence.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the
MEDPROMEDPRO interface if it is not already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the lin kage between the internal ID and the port.
Continued on next page