DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-88display test-schedule
2
display test-schedule
Automatic Transmission Measurement System (ATMS) provides advanced
maintenance proced ures for monitoring system trunk facilities. This system
performs transmission tests on system t runks to determine if trunks are
performing satisfac torily. These tests can be initiated in two ways:
Adjustable
Make/Break Ratio This field can be of p articular importance when using a modem that
may be transferable from c ountry to country. The intent of this field
is to control the make/break ratios o f pulses and DTMF dialing. The
Intel product information has support for the different make /break
options for pulse di aling only.
Intel uses the option “&P0” to selec t a ratio of 39% make and 61%
break for communication wi thin the U.S. and Canada. The option
“&P1” sets a ration of 33% make and 67% b reak for the U.K. and
Hong Kong.
This field is 5 characters long and is case in-sensitive. ( )
Dial Command This field simply denotes the d ialing command of the modem. This
is a fairly standard comm and. (D)
No Answer
Time-Out Most off-the-shelf external modems prov ide a timer that abandons
any outbound data c all after a predetermined interval. Some
modems provide for this tim er to be disabled , thus allowing an
outbound call to ring indefinitely. AT&T Paradyne does not provide
this capability with thei r modem line, because it is generally
undesirable to have an outb ound call attempt ring indefinitely.
The internal modem must have this parameter disab led or set to at
least 255 seconds.
This is a non-administrable parameter. For the external m odem
connection, this paramete r will be the first initialization string to b e
transmitted to the external modem. This field will be visible on the
administration form in disp lay mode only.
This hardcoded constant can be overridden for type approval
applications, sp ecifically in the U.K and other Western European
nations, by the use of the “Misc . Init. Param:” field. (S7=255)
demand user enters command at the System Adminis tration
Terminal (SAT) to initiate a test immediately
scheduled schedules tests through a sc hedule form to automatic ally
initiate tests at a predetermined time