DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-422DATA-BD (Data Channel Processor Circuit Pack)
3
be completely normal during heavy traffic p eriods. However, if this error
type is logged when the circuit pac k is being lightly used, it may indicate a
problem with the circui t pack or the equip ment attached to it.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the table b elow. By clearing
error codes associated with the
NPE Audit Test
, for example, you may also clear
errors generated from other tests in the testing sequence.
Note:
a. Refer to “DATA-CHL” and “SW-CTL” for other tests associated with
DATA-BD maintenance.
NPE Audit Test (#50)
The system sends a message to the on-b oard microprocessor to u pdate the
network connectivity information for all the NPEs on the circuit pack.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
NPE Audit Test (#50) (a) X ND
Control Channel Loop Around Test (#52) X X ND
Table 3-181. TEST #50 NPE Audit Test
Error
Code
Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
2100 ABORT Could not allocate the necessary system resources to run this test.
1019 ABORT Test already in p rogress.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The circuit pack’s NPEs have been updated with their translation.