DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-311BRI-SET, ASAI-ADJ, BRI-DAT
3
BRI Layer 3 Query Test (#629)
This test is used to check the ap plication layer communi cations between the
switch and the endp oint or adjunct.
For BRI endpoints, an applica tion message containing the ap propriate endp oint
service state is sent by the switc h to the endpoint. The endpoint resp onds with an
acknowledgment to the a pplication messag e.
For ASAI and Lucent adjuncts, this test is not e xecuted from the administration
terminal. Rather, a query message is automatic ally sent by the switch ever y two
minutes. Failure of the switch to receive a response to a q uery from the adjunct is
logged in the Hard ware Error Log.
Table 3-136. TEST #629 BRI Layer 3 Query
Error
Code
Test
Result Description/ Recommendation
1005 ABORT The endpoint’s MIMs Supported? field is administered to
"no."
1. Use the change station extension command to change
the parameter only if the endpoint documentation reflects
support for ISDN-BRI Management and Maintenance
Procedures.
1113 ABORT The signaling link between the switch and the endpoint or
adjunct is down.
1. Use the test port PCSSpp long command to clear any
errors which prevent establishment of the signaling link.
2. Examine the results of Test #626, which is executed with
the command. If this test aborts or fails, follow the repair
procedure for the Signaling Link Status Test.
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Consult the repair procedure for PKT-CTRL (Packet
Control Circuit Pack) Maintenance documentation.
Continued on next page