DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-80AN-LN-PT (Analog Line Port)
3
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Resolve any TONE-PT errors in the error log.
2. If there are no TONE-PT errors, retry the command at 1-minute
intervals no more than 5 times.
3. If the test continues to abort, escalate the problem.
Any FAIL The NPE of the tested port did not conference the tones correctly. This
causes noisy and unreliable connections.
1. Issue the display port UUCSSpp and the status station
extension
commands to determine if the station is idle.
2. If the station is idle, issue the test port UUCSSpp command for this
port.
3. If the test continues to fail, issue the busy port UUCSSpp and the
release port UUCSSpp commands, and then retest.
4. If the test still fails, replace the board.
PASS The port can correctly conference multiple connections. Investigate
user-reported troubles on this port by running other port tests; by
examining station, trunk, or external wiring; or by inspecting the station.
0NO
BOARD The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the
list configuration command, and resolve any problems.
2. If the board is correctly inserted, issue the busy board UUCSS
command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This re-establishes the
link between the internal ID and the port.
6. If this is not the case, check to make sure that a valid board is
inserted.
Table 3-31. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page