DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-329test cdr-link
2
Output
The following example shows the outp ut for the test cdr-link primary command.
The responses display on a test-b y-test basis with one line of data f or each test
result.
Field descriptions
Port Not applicab le (always blank)
Maintenance
Name The type of MO being tested: p rimary cdr-link= PRI-CDR; secondary
cdr-link = SEC-CDR
Alt. Name Not applicab le (always blank)
Test No The test being executed
Result Test result: Pass, Abort, Fail, Disabled
Error Code Numeric code exp laining why the release failed or ab orted. Refer to the
detailed list of the cod es by test number for eac h MO.
test cdr-link primary short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
PRI-CDR 215 PASS
Command Successfully Completed