Maintenance Objects
3-106ANN-BD (Announcement Circuit Pack)
3
1024 ABORT Announcement circuit pack bloc ked the test because an announcement
download is in progress. If an announcement download is in progress, a
status data-module <announcement data extension> command should
show that the announcement data port is connected to a NETCON data
channel, and the "card-in-use" LED for the memory card should be on (to
determine the extension of the announcement data module, use the list
data-module command). See Note (a) at end of table for more information.
1. Wait until download is finished (can take up to 45 minutes), and then
run the test again.
2. If the test continues to abort and there is no download in progress,
escalate the problem.
2000 ABORT Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the
maintenance strategy recommended for this error type.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2007 ABORT The Announcement circuit pack thinks that Port 1 or Port 9 is busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow the Announcement Port
maintenance procedures for Ports 1 and 9.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1-3 FAIL Test failed. The error code indicates at which speech c ompression rate the
test actually failed (one being the first rate tested, three being the last).
1. Reset the circuit pack via the reset board PCSS command and then
run this test again. If the test still fails, replace the circuit pack (see
Warning) and run this test again.
2. If there are recurring alarms on this circuit pack caused b y this test
failing, replace the circuit pack even if Step 1 works (see Warning).
!WARNI NG:
Replacing the circuit pack results in loss of integrated announcements. See ‘‘General Notes’’ near the b eginning of this Maintenance procedure.
Table 3-40. TEST #210 140AY Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page