DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-20ADX16D-P (16-Port AUDIX Digital Port)
3
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy por t or link. This is an off-board problem
that is detected b y the port circuit. If this problem exists, replac e the
circuit pack (s ee caution at the beginnin g of this section). Once t he
problem is resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the
voice port. When an error with the link is detec ted, an on-board c ounter is
incremented. Also see Note a, ab ove.
c. This is an internal type error that occ urs when an audit request fails.
d. The port is busied-out by command. Release the port with the release
port PCSSpp command.
Table 3-8. DEFINITY AUDIX Digital Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test port PCSSpp sh r 1
1(a) 40987 None WARNING OFF
1(b) 1 to 20 None WARNING OFF
15(c) Any None
18(d) 0 busyout port PCSSpp WARNING OFF release port PCSSpp
23(e) 0 None WARNING OFF
130(f) None WARNING ON test port PCSSpp sh
257(g) 40971 None
513(h) Any None
1537(i) 40968 None WARNING OFF
1793 Voice and Control
Local Loop TEST
(#13)
MIN/ WRN2
2. Minor alarms may be downgraded to Warning alarms based on the values used in the set options
command.
ON test port PCSSpp l r 3
2049 NPE Crosstalk Test
(#9) MIN/ WRN2ON test port PCSSpp l r 3
2305(j) 40967 None
3840(k) 40965 None
3840(l) 41029 None