3-1295XXX-BD (Common Port Circuit Pack)

3
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack and is executed as part of the long test sequence only for the Tone-Clock circuit pack and DS1 interface circuit pac ks. All other common circuit pa cks can be reset with the reset board PCSS c ommand.
Table 3-555. TEST #53 SAKI Sanity Test
Error
Code
Test
Result Description/ Recommendation
none ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT Wrong circuit pack configuration to run this test. This error applies only to
DS1 interface circuit packs. It means the DS1 interface circuit pack is
providing timing for the system and, therefore, it cannot be reset without
major system disruptions.
1. If the circuit pack needs to be reset, set synchronization to another
DS1 interface circuit pack or the Tone-Clock circuit pack and try again.
Refer to SYNC (Synchronization) Maintenance documentation.
1015 ABORT Port is not out-of-service.
1. Busy out the circuit pack.
2. Execute command again.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pac k.
PASS The circuit pack initializes correctly.
1. Run the Short Test Sequence.
any NO
BOARD This is normal if the test is being done when (a) the circuit pack is not
physically in the system or (b) the system is booting up. Otherwise, there is
some inconsistency between the physical configuration and the data kept
in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5 times.