DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-667EXT-DEV ADMIN? Y (External Device Alarm)
3
Table 3-278. TEST #120 External Device Alarm Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 time.
1035 ABORT The Expansion Port Network containing this equipment is not available
Look for and resolve all Expansion Port Network problems with this
cabinet.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 time.
2. (Maintenance Board) If the test continues to ABORT with error code
2000, check for system powering problems with the A carrier. Then,
repeat the test.
3. (Maintenance Board) If the test continues to ABORT with a 2000 error
code, check for and resolve all maintenance circuit p ack errors. Then,
repeat the test.
2029
2100
2319
2320
2500
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
ANY FAIL The External Device Alarm has been activated by the external device.
1. Clear the major alarm on the external device, and rerun the test.
2. If the test still fails, then disconnect the External Device Alarm Leads
from the Maintenance circuit pack and rerun the test.
3. If the test still fails, then there is a problem with the analog external
device alarm port or the Maintenance circuit pack that is reporting the
alarm. This circuit pack should be replaced. There are failures that can
occur on the Maintenance circuit pack that
will not
be detected by
their respective maintenance, but which will cause many environment
tests to fail. If many environment tests are failing, the suspect circuit
pack should be replaced and the test rerun.
PASS If there is a problem with the external device, but the administered analog
line external device alarm, or the administered Maintenance circuit pack
connected to the device reports no alarm, then the External Device may
not be properly reporting the problems or the External Device may not be
properly connected to the External Device Alarm Lead.
Continued on next page