DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-290status packet-interface
2

Field descriptions, page 1

Only those fields that are different from ‘‘status link n’’ are listed here.
status packet-interface
This command displays the status of the packet-interface portion of the TN798
processor circuit pack along with link inform ation. Link status information
including total, ac tive, and failed links also d isplay. When the packet-interface is
out-of-service or uninstalled, it i s not used to establish and mainta in links; when it
returns to in-service status, new links are again ass igned to it.
Output
The following example shows the output from the status p acket-interface
command.
Destination Name of the destination (assigned with the add/change
data-module command)
Destination Status in-service/idle, in-servic e/active, disconnec ted, out-of-service,
in-service, inactive, acti ve, idle
AC Active channel
Destination Port Administered port loc ation (assigned with the add/change
data-module command)
Destination
Extension Administered destination ex tension number (assigned with t he
add/change data-module command). This may be replaced by
Trk/Mem data (like the PI status line form) depending upon the
type of destination.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status packet-
interface
print
Report sent to printer init
inads
craft
none none
status packet-interface
PACKET INTERFACE STATUS
Location: 01A
Service State: in-service
Total Links: 32
Active Links: 32
Failed Links: 0