DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-860OPS-LINE (DS1 OPS Line)
3
Audit and Update Test (#36)
This test sends port level translation d ata from switch processor to the DS1
Interface circuit p ack to assure that the trunk’s translation is c orrect. Translation
updates includ e the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of the trunk as kept in the DS1 Interface circ uit
pack and in the switc h software.
PASS The port can correctly conference multiple connec tions. User-reported
troubles on this port should be investigated using other port tests and
by examining station, trunk, or external wiring.
0NO
BOARD The test could not relate the internal ID to the port (no board). This
could be due to incorrec t translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-372. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page