DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-862OPS-LINE (DS1 OPS Line)

3
DS1 OPS Switchhook Inquiry Test (#312)

This test initiates the Switchhook Audit Test. The test queries the switchhook state

of the Off-Premises-Station in switch software. If the state in switch software

disagrees with the state on the DS1 Interfac e circuit pack . The state in the switch

software is updated to matc h the state on the DS1 Interface circuit p ack.

PASS Trunk translation has been updated successfully. The current trunk
states kept in the DS1 Interface circuit pack and switch software are
consistent.
0NO
BOARD The test could not relate the internal ID to the port (no board). This
could be due to incorrec t translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-374. TEST #312 DS1OPS Switchhook Inquiry Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use the status station
command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 3-373. TEST #36 Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page