DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-257ATM-TRK (Circuit Emulation Service Circuit Pack)
3
Table 3-114. ATM Crosstalk Test (#1298)
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate required system resources.
1. Retry the command up to 5 times at 1-minute intervals.
1002 ABORT Could not allocate time slots. Traffic may be heavy or time slots may be
out-of-service.
1. Identify and correct TDM-bus errors (if any) using the procedures in the
TDM-BUS maintenance object.
2. Repeat the test up to 5 times at 1-minute intervals.
1003 ABORT Could not allocate a tone receiver. Too few tone detectors installed or tone
detectors out-of-ser v ice.
1. Identify and correct any TTR-LEV errors listed in the Error Log.
2. Resolve any TONE-PT errors listed in the Error Log.
3. Retry the test up to 5 times at 1-minute intervals a maximum.
2000 ABORT Test timed out.
2100 ABORT Could not allocate required system resources
1. Retry the command 5 times at 1-minute intervals.
1962 ABORT All TALKER DSPs are busy.
2302 ABORT Inconsistent uplink message from the ATM-TRK circuit pack.
1. Retry the command up to 3 times at 1-minute intervals.
2752 ABORT The circuit pack in this location is not a TN2305A/2306A.
1-8,
None FAIL ATM-TRK circuit pack writing on unauthorized TDM time slots. The error
code indicates the number of TALKER DSPs that are at fault. These DSPs
cannot be used again until this test of the ATM DSP Test (#1293) tells the
circuit pac k to use them again.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the failure persists, replace the circuit pack.
1-8 PASS ATM-TRK circuit pack not talking to un-authorized time slots on the TDM
bus. The error code indicates the number of TALKER DSPs tested.
Continued on next page