3
The Deactivated state indica tes a problem with the BRI-LINE circuit pac k. When
in this state, the Level 1 interface is id le and is not trying to c ommunicate with the
BRI endpoints or adjunct. When an ISDN-BRI port is placed in the out-of-servic e
state, Level 1 is also put into the Deactivate d state. This could be d ue either to
the system detecting a fault with the port or to a busyout port PCSSpp reque st.
Table 3-122. TEST #621 Level 1 Status Inquiry
Error
Code
Test
Result Description/ Recommendation
1187 ABORT The board, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port
and BRI-BD (board busied out). If this error type is present for
BRI-PORT only, then release the port via the release port pp
command and run the test again. If the error is present for both BRI-BD
and BRI-PORT, then release the board via the release port PCSS
command and run the test again.
NOTE:
When you release a port, you release all p orts associated w i th it. If
certain ports stil l need to be busied out, use the release port
PCSSpp command to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board PCSS and reset board PCSS
commands.
2. If the test aborts again, replace the circuit p ack.
2012 ABORT Internal system error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.