DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-286BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)

3
Electronic Power Feed Inquiry (#622)

This test queries the BRI-LINE circuit pack for the sta tus of the Electronic Power

Feed (EPF) supplied to a BRI endpoint or an ASAI or Lucent adjunc t. If the EPF is

on and no overcurrent cond ition exists, this test passes. All other states are not

normal and indicate a problem with the endp oint or adjunct, the wiring to the

endpoint or adjunc t, or the BRI-LINE circuit pack. This test is not run on the

TN2208 circuit pack or the TN2198 and will always return a pass for a TN2198.

The TN2208 has no power feeds.

Table 3-123. TEST #622 Electronic Power Feed Inquiry
Error
Code
Test
Result Description/ Recommendation
1005 ABORT This test is not valid for this port type. Ports on the TN2208 cannot run
this test because this board does not have an electronic power feed.
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board PCSS and reset board PCSS
commands.
2. If the test aborts again, replace the circuit p ack.
2012 ABORT Internal system error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL The BRI-LINE circuit pack reports that it has detected an overc urrent
condition and has turned off the EPF.
1. As necessary, check and repair the wiring between the c ircuit pack
and the endpoint or adjunct. Check the endpoints and rep lace one
or both sets if the sets are drawing too much current. Execute the
test port PCSSpp command and review the resul ts of the EPF
Inquiry Test to verify the repair. If this test is still failing, proceed to
Step 2 .
2. Execute the test port PCSSpp command, and review the results of
the Level 1 Status Inquiry Test. If this test is also failing, then follow
the repair procedure for the Level 1 Status Inquiry Test.
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board PCSS and reset board PCSS
commands.
2. If the test aborts again, replace the circuit p ack.
PASS The Electronic Power Feed Inquiry Test reports that the EPF is on.
Continued on next page