3
Table 3-295. TEST #60 Hybrid Line Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT A request for a remote station lamp update aborted even though all
internal resources were correctly allocated.
1. Look in the error log for error type 18 (port busied out) for this port. If
this error type is present, release the port via the release port
PCSSpp command or the release station extension command, and
then run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
2 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
3 ABORT The station is in a ready for service or an out of service state. This may be
due to wiring or an unplugged or defec tive set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extensio n number of the port. Use the status stat ion
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting. Attendants are
always in use (off-hook) if the handset is plugged in and the port is not
busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Hybrid Line Lamp Updates completed successfully.
1. If complaints still exist, investigate by using other circuit pack tests,
and by examining the station, wiring, and connections.