DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-699HYB-LINE (Hybrid Line)

3
Hybrid Line Lamp Updates Test (#60)

For this test, the software lights the lamps on the terminal b ased on the status

record contained in the processor. The lamp upd ates run only if the station is

in-service.

PASS Hybrid Line Remote Digital Loop Around Test passed. The hybrid circuit
pack is sending and receiving p roper messages to and from the voice
terminal.
1. If problems still exist, investigate using other circuit pack tests and by
examining the station, wiring, and connections.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-294. TEST #59 Hybrid Line Remote Digital Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page