3-17ADX16D-B (16 Port AUDIX Circuit Pack)
3
ADX16D-B (16 Port AUDIX Circuit
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack combination operating in 16 port mode digital (DP). For
circ uit-p ack- level prob lems, s ee “XXX- BD (Com mon Por t Circ uit Pac k)”.
Port-level maintenance is covered b y ADX16D-PT.
DEFINITY AUDIX consists of 2 circuit packs that occup y 4 slots on a port carrier.
The tests described in this manual apply only to switch-sid e maintenance which
tests circuit pack components related to the TDM bus interfac e. The AUDIX
system has an extensive maintenance strateg y of its own that is described in

DEFINITY AUDIX System Maintenance

, 585-300-110.
MO Name (in
Alarm Log)
Alarm
Level Initial Command To Run1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for
example, A, B, or C); SS is the address of the slot in the carrier where the circuit pack is
located (for example, 01, 02, ..., etc.).
Full Name of MO
ADX16D- B MINOR test b oard PC SS sh AUDIX Ci rcuit Pack
ADX16D- B WARNING test b oard PC SS sh AUDIX Ci rcuit Pack