DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-531DIOD-DS1 (DS1 DIOD Trunk)
3
Port Audit and Update Test (#36)
This test sends port level translation d ata from switch processor to the DS1
Interface circuit p ack to assure that the trunk’s translation is c orrect. Translation
updates includ e the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circ uit pack
and in the switch software.
DS1 CO Dial Tone Seizure Test (#314)
DS1 CO Dial Tone Seizure Test checks the trunk’s signaling c apability p rovided
by the DS1 Interface circuit pack. The maintenance software initiates the test b y
sending a ‘‘seizure’’ message to the DS1 Interface circuit pac k and expects an
‘‘active’’ reply from the DS1 interface circ uit pack. If the ‘‘active’’ messag e is
received, then the test passes. If n o message is received and the timer expires,
the test is aborted. If the DS1 Interface c ircuit pack send s a ‘‘reorder’’ message
back to maintenance software, then th e test fails.
Table 3-224. TEST #36 Port Audit and Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack and switch software are consistent. If
the trunk is busied out, the test will not run but will return PASS. To verify
that the trunk is in-service:
1. Enter the status trunk command to verify that the trunk is in-service. If
the trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to step 2.
2. Enter the release trunk command to put the trunk back into in-service.
3. Retry the test command.
Continued on next page