DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-71ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
3
FAIL The terminal equipment is not connected to the circuit pack or the ringing
generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, refer to the RING-GEN (analog ring generator) Maintenance
documentation.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the set may be defective. Check the set, and
replace it, if necessary.
5. Some terminal equipment (such as a modem) could fail even when it is
connected properly. If this is the case, disable the test using the
change station extension command (enter ’n’ into the ’Test’ field).
Note that this action also disables tests 6, 7, 161, and 35 on this port.
PASS The station is connected properly to the switch. This test may also pass if
no terminal equipment is connected and the terminal is located far from the
switch (that is, it is off-premises). User-reported troubles on this port should
be investigated by using other port tests, by examining station wiring, by
examining the station, and by ensuring that the terminal is correctly
translated as off-premises or on-premises.
NOTE:
This test always passes for TN742 Analog circuit packs prior to
Vintage 6.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-28. TEST #48 Station Present Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page