DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-281BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
3
Electronic Power Feed Restoral Test (#620)
This test attempts to restore the Electronic Power Feed (EPF) on an ISDN-BRI
port twice. In this test, the p rocessor requests that the EPF be turned on for a
given port. An attempt is ma de to turn on the power unit to the station or ad junct.
If no current is being drawn by a station, this probably indicates that the station is
not connected. No c urrent being drawn b y an adjunct is the normal c ondition. If
an overcurrent condition is sensed (that is, too much current is being drawn), this
condition may indic ate a short in the wiring to the end point or adjunct.
Depending on what c ondition is sensed, a messag e is returned stating that either
the EPF was turned on successfully with no prob lems or that an overcurrent
condition is sensed. This resp onse is reported by t he Electronic Power Feed
Inquiry (#622), which follows in the testing sequence. EPF Restoral is attempted
again by this test five second s later. This test always passes for the TN2198
because it has no EPF. This test will always abort when run on the TN2208.
7, 8 FAIL As stated previously, this test runs a Conference Circuit Test on each
B-channel. A failure here indicates that one of these conference tests
failed; Error Code 7 means that the test failed on B1; Error Code 8 means
that the test failed on B2.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other
ports on the circuit pack are not in use. Reset the circuit pack by
issuing the busyout board PCSS and the reset board PCSS
commands.
2. If the test fails again, replace the circuit pack.
PASS The BRI Port Local TDM Loop Around Test has passed.
Table 3-120. TEST #619 BRI Port Local TDM Loop Around — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page