DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-732ISDN-SGR (ISDN-PRI Signaling Group)
3
3 FAIL Both the primary and secondary Channels are down.
1. Examine the results of the Primary and Secondary Signaling Link
Hardware Tests (#636 and #639) and follow recommendations
provided there.
2. If tests #636 and #639 pass, the Layer 2 Query test may still fail if the
Signaling Channels at the far end has not been administered correctly
or if the Signaling Channels have been busied out. Verify that the
Primary and Secondary Signaling Channel (D-channels) at the far end
have been administered correctly. Verify that the DS1 ports used for
the Primary and Secondary D-channels have not been busied out at
the far end.
PASS The Primary Signaling Channel is up and, if administered the Secondary
Channel is up.
Table 3-308. TEST #647 Layer 2 Status Query Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page