DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-409CO-TRK (CO Trunk)

3
Port Audit Update Test (#36)
This test sends updates of the CO port trans lation for all ports on the circuit p ack that have been translated. The upd ate is non-disruptive and guards against possible corrup tion of translation data contained on the circuit pac k. No response message is expec ted from the circuit p ack once it rece ives translation updates. The port translation d ata includes: g round or loop start trunk, tone or rotary dialing trunk, rotary d ialing inter-digit timing , network balance R/RC, and disconnect timing .
Table 3-177. TEST #36 Port Audit Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1006 ABORT The port has been placed out of service, perhap s by craft busyout. Use the
display port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait until the port is
idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
2100 ABORT System resources required to run this test were not available.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS This test passed. Translation information was successfully updated on the
circuit pack. User-reported troubles on this port should b e investigated by
using other port tests and by examining trunk or external wiring. If the trunk
is busied out, the test does not run, but returns PASS. To verify that the
trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk command to put the trunk back into in-service.
3. Retry the test command.
Continued on next page