DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-306status system
2
SYSTEM CLOCK Shows which Tone-Clock supplies the s ystem clock for the cab inet
displayed:
active: Tone-Clock active and supplying system clock
down: Tone-Clock failed some maintenance activity and cannot
supply the system clock for this cabinet.
<blank> If si mplex, then the 1B Tone-Clock for the PPN displays
blank; if no EPN, then both the 1A and 1B Tone-Clock for this
EPN display blank.
SYSTEM TONE Shows which Tone-Clock circuit pac k supplies the system tones for
the cabinet being displayed.
active: Tone-Clock active and supplying system tones
down: Tone-Clock failed some maintenance activity and cannot
supply the system tones for this cabinet.
<blank> If si mplex, then the 1B Tone-Clock for the PPN displays
blank. If the system does not have an EPN, then both the 1A
and 1B Tone-Clock for this EPN display blank.
TDM The TDM Bus identifier (1A and 1B)
SERVICE STATE Operational state of the TDM Bus circuit pack:
in: TDM Bus installed and is in-service
out: TDM Bus failed certain maintenance tests and has been
removed from service
CONTROL
CHANNEL IWhether the control channel is on this TDM Bus (y or n)
DEDICATED
TONES Whether the dedicated tones are on this TDM Bus (y or n)
PKT Packet Bus identifier (1). Refer to Packet Bus Maintenance
descriptions for more information.
SERVICE STATE The operational state of the Packet Buses:
in: Packet Bus in-service and op erating normally.
out: Packet Bus failed certain mainte nance tests and has been
removed from service.
<blank> System d oes not have the Packet Bus feature.
BUS
ALARMS-MAJOR Whether Major alarms exist for packet bus c omponents (y or n)
BUS