DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-113ATM Tips
1
Figure 1-41. Screen output for the show signaling summary command
a. If an A500 port to which a DEFINITY port network is attached is not
listed in this display, it is likely that the p ort was administered
incorrectly as having no UNI si gnaling (admin link command).
Ensure that fields listed have the values indi cated below.
2. If the A500 was administered using h ard-coded PNNI routes to identify
each endpoint, enter show signaling routes on the A500 cons ole. Figure
1-42 shows the screen output from the c ommand.
Field Value
IntType Network
If it is User, links will not come up between the PPN and
the EPN.
Signaling UNI3.1
If it is UNI3.0, links will not come up between the PPN
and the EPN.
ILMI Preferred value of is No, however this alone does not
prevent links from coming up between the PPN and an
EPN.
SAP State May or may not be UP. Their values depend on more than
just whether the port was marked as UP. (See
highlighted data for SAP State in Figure 1-41.)
A500:show signaling summary
Port loc VCI SAP IntType Signaling ILMI SAP State State
------ ------- --- ------- ----------- ---- ------------ -----
A1.1 1 1 Network UNI3.1 No UP UP
A1.2 2 2 Network UNI3.1 No UP UP