DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-369CLSFY-PT (Call Classifier Port)
3
1002 ABORT The system could not allocate time slots for the test connection. This
situation could occur when the system is heavily loaded. If the system is
not heavily loaded, then test the TDM-BUS via the test tdm [1|2]
command. Refer to the TDM-BUS (TDM Bus) Maintenance documentation
for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a Tone-Clock circuit pack for the test
connection. This situation could occur when the system is heavily loaded
or if a Tone-Clock circuit pack is not present in the port network when this
test is executed.
1. Verify the existence of a Tone-Clock circuit pack in the same port
network.
2. If a Tone-Clock circuit pack is missing, install one in the same port
network.
3. Allow approximately 1 minute for the Tone-Clock circuit pack
maintenance to run on the newly inserted Tone-Clock circuit pack.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2006 ABORT This abort code indicates that the active Tone-Clock circuit p ack might not
be functioning properly. If there is more than one Tone Detector circuit
pack in the system, then the problem can be either with the Tone-Clock
circuit pack or the Tone Detector circuit pac k. This could also be caused
by the companding mode ad ministered for the system not matching that of
the Tone Detector circuit pack.
1. Make sure that the companding mode of the system matches that of
the Tone Detector (TN748 for mu-law systems and TN420 for A-law
systems).
2. Test the active Tone-Clock circuit pack in the port network. This test is
being executed via the test tone-clock qualifier system technician
command. ("qualifier" is the carrier of the active Tone-Clock circuit
pack to be tested. Valid qualifiers are: a, b, 1a, 1b, 2a, and 2b.) Refer
to the ‘‘TONE-BD (Tone-Clock Circuit Pack)’’ Maintenance
documentation for details.
3. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-164. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page