DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-82display system-parameters maintenance
2
Cleared Alarm
Notification Enables the switch to originate a c all to the OSS and send an
alarm resolution message whenever all p reviously-reported
Major and Minor alarms are resolved. Alarm Origination must be
activated in order for Clear ed Alarm Notification to work. (no)
Restart Notification Enables the switch to originate a c all to the OSS and report any
system restarts caused by problems with the switch.
Suspension Threshold The threshold for suspending Cleared Alarm Notification (1-15).
Some problems may cause alarms to b e generated and then
resolved repeatedly. To d etect these problems (b y not sending
additional Cleared Alar m notifications to indicate a p roblem-
free system), the switch suspends Cleared Alarm Notification
when it has reported this ad ministrable number of Cleared
Alarm notifications in a 24-hour period . A suspended Cleared
Alarm Notification is only enabled again with a successfu lly
completed “ logoff” command, a sy stem reset, or when the
threshold is changed . This field is irrelevant if Cleared Alarm
Notification or Alarm Origination is disabled.
Test Remote Access
Port Specifies whether testing of the remote access port on the
SYSAM ci rcui t pac k is en abled . This field shoul d rea d yes
whenever there is an INADS line connected to the switch and
there is a maintenance contrac t in effect so that alarm
origination capab ility is maintained.
CPE Alarm Activation
Level Indicates the minimum level (Major, Minor or Warning) at which
the Customer-Provided Equipment (CPE) alarm is activated . If
the level is none, the CPE does is not activated for any alarm.
(none)
NOTE:
The CPE alarm is always activated when the switch goes
into Emergency Transfer, regardless of the CPE Alarm
Activation Level setting.
Customer Access to
INADS Port Provides the capability to prohibit access to system
administration and maintenanc e interface, via the INADS port
when using customer login ID’s. This field can only be activated
by Lucent services throug h system-parameters maintenance
administration.(no)
Repeat Dial Interval
(MMS) Indicates the number of mi nutes that the system must wait
before attempting anot her call origination to an OSS. This timer
is triggered b y the lack of a far-end acknowled gment. (7)