DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-952PR-MAINT (Maintenance Processor)
3
Table 3-412. TEST #228 MTP Manager I Loop Around Test
Error
Code
Test
Result Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Main tenanc e doc ument ation f or a de scri ption of thes e
error codes.
1000 ABORT The system software resources required for this test are not available.
2000 ABORT Response to the test request was not received within the allowable time
period.
2033
2034 ABORT Internal system error
Port bu sy
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Manager I channel failed the Loop Back Test. The Manager I is
probably unusab le for administration or maintenance. The EPN
Manager I, if available, or remote ac cess can still be used .
1. Repeat the command at one m inute intervals a maximum of 5
times.
2. If the test continues to fail, repla ce the Processor circuit pac k at
your earliest convenience. Refer to Chap ter 1 “Reliability
Systems: A Maintenance Aid” for information on how to rep lace a
circuit pack in the control carrier.
!WARNI NG:
If the TN786B circuit pack mus t be replaced, and if there is a blank in the Expansion Memory ci rcuit pack slot (that is, in the slot immediately to the right of the TN786B c ircuit pack), remove the blank before removing the c ircuit pack. Otherw ise, the circuit pac k and/or the two connectors that are used to connect the Expansion Memory c ircuit pack (if availab le) might
become damaged.
PASS The Manage r I channel passed the Loop Back Test.
1. If the PPN Manager I is not usable, chec k the Manager I itself,
along with the cabling .
Continued on next page