DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-347test inads-link
2
normal retry mechanism is followed, whic h means an attempt to make a call to
INADS to report the error takes place 7 minutes later. An I NADS trouble ticket is
created only if the connec tion is successfully established and a message is sent
to the system acknowledging that INADS received the system message.
The Maintain Process Circuit Packs field must be set to yes on the inads
and technician p ermission forms. This will provide pe rmissions to execute the
test inads-link command. This field c an be changed b y executing a change
permission login command.
No alarms are raised on the system and attend ant alarm and acknowled gment
lamp states are not changed as a result of the test inads-link command. The test
does not run during p eriodic or sched uled maintenance.
Output
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test inads-link
1
2
First OSS telephone number
Second OSS telephone number
Examples:
test inads-link
test inads-link 1
test inads-link 2
init
inads
craft
nms
1st OSS
number none
Command successfully completed Te st pa ssed
Command failed Link was up, there was an active alarm that
the switch needs to report, or there was a
problem with the call.
NOTE:
An entry is made in the error log
describing why the inads-link test failed.