DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-963PRI-CDR/SEC-CDR (PRI-CDR Link)
3
If the destination is "eia," then look for PR-MAINT errors in the Hardware
Error Log. If present, refer to ‘‘PR-MAINT (Maintenance Processor)’’
Maintenance documentatio n.
4. Is a data channel on the TN798 Processor circ uit pack in the
in-service/idle state?
Enter list data command and find out the extension numbers of data
channels. Enter status data extension command and m ake sure that at
least one data channel is in the in-servi ce/idle state. If no data c hannel is
available, then look for DATA-CHL/DATA-CON/DATA-BD errors in the
Hardware Error Log. If present, refer to ‘‘DATA-BD (Data Channel
Processor Circuit Pack)’’.
5. Is the external CDR output device availa ble?
Make sure that the CDR output device is on-l ine and ready for service.
Check the physical c onnectivity between Data Mod ule and the CDR
output device or b etween the EIA port on backp lane of the switch and the
CDR output device.
It is recommended to b usy out the CDR link before executing mainte nance tests
over the CDR link. If the CDR link is busied out, then all CDR link maintenance
actions are deactivated . The interference to tests of other MO is off.
Error Log Entries and Test to Clear Values
Table 3-420. CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value1
020 Any Any Any test cdr-link
primary|secondary sh
18 (a) 0 busy out cdr WARNI
NG OFF release cdr-link
primary|secondary
primary | secondary
25 (b) 0
3 to 6
9
99
255
Link Retry Test (#215) MIN OR/
WARNI
NG3
OFF test cd r-link
primary|secondary l
513 (c) 0
3 to 6
9
test cdr-link
primary|secondary
Continued on next page